Unit 106, 7927 River Road, Delta, BC
Mon-Fri 09:00 AM - 05:00 PM
Unit 106, 7927 River Road, Delta, BC
Mon-Fri 09:00 AM - 05:00 PM
Shopping Cart
  • No products in the cart.
  • Listed Client – INTL-202260-C01

    CERTIFICATE OF COMPLIANCE

    Certificate Number: INTL-202260-C01 Project Number: INTL-202260-C01
    Date Issued: February 09, 2024 Client Number: INTL-202260
    Certification System: Type 3 Issued To: Sensor Electronics Corp.
    12730 Creek View Avenue Savage MN, 55378 USA
    Certification Body: International Testing Laboratory Inc. Issued By: Certification Manager

    The products listed below are eligible to bear the INTL Certification Mark with adjacent indicator 'C' and ‘US’, and the subject area as shown below which represents that the product has been evaluated by an accredited CB to the applicable CSA and UL Standards respectively.

    Product: SEC Millenium Hawk Infrared Gas Detector
    Model: SEC Millenium Hawk Infrared Gas Detector with SEC 3100 and SEC 3120.
    Electrical Ratings: Input: 18 to 32 VDC; 3.6 Watts Max
    Class I, Division 1, Groups B, C, D T5 - 40°C ≤Tamb ≤70°C IP66
    Standard: CSA-C22.2 No. 61010-1-12/A1:18 (R2022)
    UL 61010-1 Ed:3
    CSA C22.2 No. 30:20
    UL 1203 Ed:5
    CSA C22.2 No. 60079-29-1:17/A1:22 (R2022)
    UL 60079-29-1 Ed: 2
    Conditions of Acceptability: - Installation of the SEC Millenium Hawk Infrared Gas Detector shall be according to the Canadian Electrical Code (CEC) and subject to acceptance by the authority having jurisdiction.
    - SEC Millenium Hawk Infrared Gas Detector shall be supplied by a Class 2 power supply or SELV power supply in accordance with CSA-C22.2 No. 61010-1-12/A1:18 (R2022) and UL 61010-1 Ed:3.
    - Enclosure suitable for outdoor environment with ingress protection rating of IP66. The presence of an IP66 rating on the product label does not signify that the equipment will necessarily detect gas during or after exposure to those specified conditions. Instruction manual shall provide guidance on determining the suitable calibration interval and maintenance requirements when exposed to conditions representative of the IP rating.
    - The SEC Millennium detector's performance requirement has been verified to align with the specifications outlined in CSA C22.2 No. 60079-29-1/UL 60079-29-1 specifically when used in conjunction with the SEC 3100 and SEC 3120 transmitter. Suitable for Pollution degree II and Over Voltage Category II.
    - Suitable Operating altitude: upto 2000m.