Voltage Dips and Interruptions Testing and Certification services in Canada
Voltage dips and interruptions are caused by sudden changes in power grid, power facility failures or loads. In some cases, there will be two or more consecutive rollovers or interrupts. The voltage change is caused by a continuous change in the load connected to the grid. If the EUT on power supply voltage changes cannot respond in a timely manner, it may lead to failures.
INTL Inc. has voltage dips and interruptions generator that is compliant to IEC 61000-4-11 and can be used to evaluate the performance of electrical and electronic equipment when subjected to voltage dips and short interruptions.
Voltage Dips and Interruptions | |
Voltage variation range | 0 ~ 120% |
Voltage change duration | 1 ~ 9999 half cycle |
Switching phase | 0 ~ 359°synchronous, asynchronous, automatic |
Built-in standard test level | 0, 40%, 70%, 80% |
Fall/rise time | 1μs ~ 5μs for abrupt changes |
Phase | 0 ~ 359°synchronous, asynchronous, automatic |
EUT Capacity | 1-phase, 20A |

To acquire a quotation, please contact us at info@intertestlab.com. For any additional assistance, you may reach us by phone at (778) 927-9696.