  • Listed Client – INTL-202225-C02

    CERTIFICATE OF COMPLIANCE

    Certificate Number: INTL-202225-C02 Project Number: INTL-202225-C02
    Date Issued: August 08, 2023 Client Number: INTL-202225
    Certification System: Type 3 Issued To: Protek Safety & Controls Ltd.
    #10, 1715 – 27th Ave NE, Calgary, AB, T2E 7E1, Canada
    Certification Body: International Testing Laboratory Inc. Issued By: Certification Manager

    The products listed below are eligible to bear the INTL Certification Mark with adjacent indicator 'C' and the subject area as shown below which represents that the product has been evaluated by an accredited CB to the applicable CSA Standard respectively.

    Product: Universal Display Module & Universal Separation Kit
    Model: Universal Display Module (UDM-00X, UDM-00X-LT)
    Universal Separation Kit (UNV-SEPKIT-001, UNV-SEPKIT-002, UNV-SEPKIT-003 (Optional accessory) UDM-001E, UDM-002E.
    Performance certified for use with Combustible gas detectors below:
    - Universal Display Module UDM-001 with Detcon Gas sensor IR700 and FP-700.
    - Universal Display Module UDM-002 with Detcon Gas sensor IR700 and FP-700.
    - Universal Display Module UDM-001 with Sensor Electronics Millenium Gas Sensor (CSA 22.2 No. 152).
    - Universal Display Module UDM-002 with Sensor Electronics Millenium Gas Sensor (CSA 22.2 No.152).
    Electrical Ratings: 10.5-30VDC 3W 100mA
    Standard: CSA C22.2 No. 213-17 (R2022)
    CSA C22.2 NO. 30:20
    UL 60079-0: Seventh Edition, Dated March 26, 2019
    UL 60079-1 Seventh Edition, Dated September 18, 2015
    CAN/CSA-C22.2 No. 60079-0:2019
    CSA C22.2 No. 60079-1:16
    Applicable general safety requirements UL/CSA C22.2 No 61010-1-12-Ed.3
    CSA C22.2 No. 152 2nd Edition, 2016
    Hazardous Location Ratings: - UDM-00X
    Class I Division 1 Group B, C, D T4 (Seals Required)
    Ex db IIB T4 Gb (Seals Required)
    Class I Zone 1 AEx db IIB T4 Gb (Seals Required)
    Class I Division 2 Group A, B, C, D T4 (No Seals Required)
    Class 1 Zone 2, Group IIC T4 (No Seals Required)
    -40°C≤Tamb≤85°C
    NEMA4X, IP66/67

    - UDM-00X-LT
    Class I Division 1 Group B, C, D T4 (Seals Required)
    Ex db IIB+H2 T4 Gb (Seals Required)
    Class I Zone 1, AEx db IIB+H2 T4 Gb (Seals Required)
    Class I Division 2 Group A, B, C, D T4 (No Seals Required)
    Class 1 Zone 2, Group IIC T4 (No Seals Required)
    -55°C≤Tamb≤85°C
    NEMA4X, IP66/68

    - UNV-SEPKIT-001 & UNV-SEPKIT-002
    Class I Division 1 Group B, C, D T4 (Seals Required)
    Ex db IIB+H2 T4 Gb (Seals Required)
    Class I Zone 1, AEx db IIB+H2 T4 Gb (Seals Required)
    Class I Division 2 Group A, B, C, D T4 (No Seals Required)
    Class 1 Zone 2, Group IIC T4 (No Seals Required)
    -40°C≤Tamb≤70°C
    NEMA4X, IP66/68

    - UNV-SEPKIT-003
    Class I Division 1 Group A, B, C, D T4 (Seals Required)
    Ex db IIC T4 Gb (Seals Required)
    Class I Zone 1, AEx db IIC T4 Gb (Seals Required)
    Class I Division 2 Group A, B, C, D T4 (No Seals Required)
    Class 1 Zone 2, Group IIC T4 (No Seals Required)
    -55°C≤Tamb≤85°C
    NEMA4X, IP66/68
    Conditions of Acceptability: - For Class I Division 1 / Zone 1 installations, the certification label states, “Seals Are Required” so the conduit entry from the field wiring side gets sealed to meet the local electrical code.
    - For Class I Division 2 / Zone 2 installations, the certification label states “No Seals Required” so the conduit entry from the field wiring side does not require a seal to be poured but must be installed to meet the local electrical code for C1D2 /Z2 installations. The certified enclosure is simply a weatherproof enclosure for these applications.
    - Housing model 8092 and 8100 has ambient rating: -40°C≤Tamb≤60°C.
    - Housing model 8101a-b (Epoxy coated cast aluminium with window or blind cover) ambient rating is: -55°C≤ Tamb ≤60°C.

    - Certified for use with the toxic gas detectors listed below, but limited to:
    - Universal Display Module UDM-001 with Detcon Toxic Gas 700 series sensors including the DM-700, IR-700-CO2, PI-700 & TP-700.
    - Universal Display Module UDM-002 with Detcon Toxic Gas 700 series sensors including the DM-700, IR-700-CO2, PI-700 & TP-700.
    - Universal Display Module UDM-001 with Sensor Electronics Toxic 3000 series gas sensors.
    - Universal Display Module UDM-002 with Sensor Electronics Toxic 3000 series gas sensors.
    - Universal Display Module UDM-001 with various manufacturer’s toxic gas detectors not requiring performance testing.
    - Universal Display Module UDM-002 with various manufacturer’s toxic gas detectors not requiring performance testing.