    CERTIFICATE OF COMPLIANCE

    Certificate Number: INTL-202109-C02 Project Number: INTL-202109-C02
    Date Issued: January 08, 2023 Client Number: INTL-202109
    Certification System: Type 3 (ISO/IEC Guide 67) Issued To: Acura Embedded Systems Inc.
    17825 64 Avenue, Unit 101
    Surrey, BC V3S 1Z3
    Certification Body: International Testing Laboratory Inc. Issued By: Certification Manager

    The products listed below are eligible to bear the INTL Certification Mark with adjacent indicator 'C' and ‘US’, and the subject area as shown below which represents that the product has been evaluated by an accredited CB to the applicable CSA and UL Standards respectively.

    Product: Industrial Panel PCs and Monitors
    Model Numbers:
    AcuPanel-10 AcuTouch-10 AcuPanel-12 AcuTouch-12 AcuPanel-15 AcuTouch-15 AcuPanel 15.6 Widescreen AcuTouch-17 AcuPanel-17 AcuTouch-19 AcuPanel-22 AcuTouch-21 AcuPanel-10W AcuBrite-12 AcuPanel-12W AcuBrite-15 AcuPanel-15W AcuBrite-10W AcuPanel-17W AcuBrite-12W AcuPanel-19W AcuBrite-15W AcuPanel-22W AcuBrite-17W RoughNeck-15 AcuBrite-19W RoughNeck-15W AcuBrite-22W RoughNeck-19W RoughNeck-22W
    Electrical Ratings: Input: 100–240 Vac, 50/60 Hz, 5 A or 2.5 A
    DC Input: 9–36 Vdc

    Class I, Zone 2, Ex ec IIB T4 Gc, −20°C ≤ Tamb ≤ 60°C; INTL22CA202109-C02

    Class I, Zone 2, AEx ec IIB T4 Gc, −20°C ≤ Tamb ≤ 60°C

    Class I, Division 2, Groups B, C and D, T4, −20°C ≤ Tamb ≤ 60°C
    Standards: CAN/CSA-C22.2 No. 62368-1 (Ed. 2.0)
    UL 62368-1 (Ed. 2.0)
    CSA C22.2 No. 60079-0:19
    CSA C22.2 No. 60079-7:16
    UL 60079-0 (Ed. 7.0)
    UL 60079-7 (Ed. 5.0)
    Conditions of Acceptability:
    • The Panel PCs and AcuBrite monitors are intended for indoor use at an ambient temperature of −20°C to 60°C.
    • When used in a classified hazardous location, the devices shall be installed and operated in an enclosure providing a suitable degree of protection for the end application. Only the display side may be exposed. All connectors shall be located inside the protective enclosure.
    • Connectors shall not be connected or disconnected when an explosive gas atmosphere is present.
    • Buttons, switches and rotary knobs shall not be operated when an explosive gas atmosphere is present.
    • The products shall only be used with a certified AC-to-DC power-supply adapter listed in the critical component list.
    • Maximum operating altitude: 2,000 m.
    • The products are intended for use by trained or instructed professionals.