  • Listed Client – INTL-202109-C03

    CERTIFICATE OF COMPLIANCE

    Certificate Number: INTL-202109-C03 Project Number: INTL-202109-C03
    Date Issued: October 21, 2022 Client Number: INTL-202109
    Certification System: Type 3 Issued To: Acura Embedded Systems Inc.
    17825 64 Avenue, Unit 101
    Surrey, BC V3S 1Z3
    Certification Body: International Testing Laboratory Inc. Issued By: Certification Manager

    The products listed below are eligible to bear the INTL Certification Mark with adjacent indicator 'C' and ‘US’, and the subject area as shown below which represents that the product has been evaluated by an accredited CB to the applicable CSA and UL Standards respectively.

    Product: PowerBrick PCs
    Model Numbers: PowerBrick Slim
    PowerBrick-DV
    PowerBrick-Mini
    PowerBrick-Bold
    PowerBrick-U
    PowerBrick-GTX
    Electrical Ratings: Power-Supply Adapter
    Input: 100–240 Vac, 50/60 Hz, 1.6 A
    Output: 12 Vdc, 1.7 A

    PowerBrick PCs
    Input: 9–36 Vdc

    Class I, Division 2, Groups B, C and D, T4, −20°C ≤ Tamb ≤ 60°C

    Class I, Zone 2, Group IIB, T4, −20°C ≤ Tamb ≤ 60°C
    Standards: CAN/CSA-C22.2 No. 62368-1 (Ed. 2.0)
    CSA C22.2 No. 213-17
    UL 62368-1 (Ed. 2.0)
    UL 121201 (Ed. 9)
    Conditions of Acceptability:
    • PowerBrick PCs are intended for indoor use at an ambient temperature of −20°C to 60°C.
    • When installed in a hazardous location, the units shall be installed within an enclosure providing a suitable degree of protection for the intended application.
    • Ordinary locations: The units shall only be used with a certified AC-to-DC power-supply adapter listed in the critical component list.
    • Hazardous locations: The units shall be powered from a DC source suitable for the intended hazardous location. The AC-to-DC adapter supplied with the unit is not suitable for use in a hazardous location.
    • Maximum operating altitude: 2,000 m.
    • The units are intended for use by trained or instructed professionals.