Unit 106, 7927 River Road, Delta, BC
Mon-Fri 09:00 AM - 05:00 PM
Unit 106, 7927 River Road, Delta, BC
Mon-Fri 09:00 AM - 05:00 PM
Shopping Cart
  • No products in the cart.
  • Listed Client – INTL-202109-C06

    CERTIFICATE OF COMPLIANCE

    Certificate Number: INTL-202109-C06 Project Number: INTL-202109-C06
    Date Issued: June 21, 2023 Client Number: INTL-202109
    Certification System: Type 3 Issued To: Acura Embedded Systems Inc.
    17825 64 Avenue, Unit 101
    Surrey, BC V3S 1Z3
    Certification Body: International Testing Laboratory Inc. Issued By: Certification Manager

    The products listed below are eligible to bear the INTL Certification Mark with adjacent indicator 'C' and ‘US’, and the subject area as shown below which represents that the product has been evaluated by an accredited CB to the applicable CSA and UL Standards respectively.

    Product: Industrial Panel PCs
    Model Numbers: Roughneck-22
    Roughneck-15
    Electrical Ratings: Input: 110–220 Vac, 50/60 Hz, 1.5 A

    Class I, Zone 2, Ex ec IIB T4 Gc, −20°C ≤ Tamb ≤ 50°C; INTL22CA202109-C06

    Class I, Zone 2, AEx ec IIB T4 Gc, −20°C ≤ Tamb ≤ 50°C

    Class I, Division 2, Groups B, C and D, T4
    Standards: CAN/CSA-C22.2 No. 62368-1 (Ed. 2.0)
    UL 62368-1 (Ed. 2.0)
    CSA C22.2 No. 60079-0:19
    CSA C22.2 No. 60079-7:16
    UL 60079-0 (Ed. 7.0)
    UL 60079-7 (Ed. 5.0)
    Conditions of Acceptability:
    • The units are intended for use only at an ambient temperature of −20°C to 50°C.
    • Connectors shall not be connected or disconnected when an explosive gas atmosphere is present.
    • Internal connections, repairs and maintenance shall be completed at the factory and not in the field.
    • Unused connectors shall be covered with the blanking caps supplied with the units and secured using the applicable set screws.
    • Repairs and maintenance shall only be performed in a non-hazardous area.
    • The units shall not be exposed to direct sunlight to prevent ultraviolet (UV) exposure.