- #105-12031 Horseshoe Way, Richmond, BC V7A 4V4, Canada
- info@intertestlab.com
Listed Client INTL-202211-C01
- Home
- Listed Client INTL-202211-C01
CERTIFICATE OF COMPLIANCE
Certificate Number | INTL-202211-C01 | Project Number: | INTL-202211-C01 |
---|---|---|---|
Date Issued: | June 2, 2022 | Client Number: | INTL-202211 |
Certification System: | Type 3 (ISO/IEC Guide 67) | Issued to: | Address Signage Company 120 Pemberton Ave, North Vancouver, BC, V7P 2R5, Canada |
Certification Body: | International Testing Laboratory Inc. | Issued By: | Certification Manager |
The products listed below are eligible to bear the INTL Certification Mark with adjacent indicator 'C' and ‘US’, and the subject area as shown below which represents that the product has been evaluated by an accredited CB to the applicable CSA and UL Standards respectively.
Product: | LED, Stationary, Single and Sectional Signs |
---|---|
Model #: | LED, Stationary, Single and Sectional Signs |
Electrical Ratings: | Input: 100-240 Vac, 60Hz, 4A, 50/60Hz
277Vac, 1.2A, 50/60Hz; Integral Class 2 Power Supply Output: 12Vdc, 192Watt, 16A |
Standards: | CSA C22.2 NO. 207:15 (R2020) |
Conditions of Acceptability: | - Markings as given in the report on the marking section. - This unit is suitable for dry and wet locations and shall not be used in hazardous location. - Wet Locations Signs shall use rubber gasket on the enclosure/body contour. Not required for Channel Letters. - Silicon is applied to seal gaps in the raceway used on Sectional Signs. (Channel Letters) |