Product: |
PCC2 Electronic Injection Controller |
Model #: |
PCC2 |
Electrical Ratings: |
Circuit 1-Control Input; 12-30 Vdc, 500 mA
Circuit 2 input / output: 15A
|
Hazardous Location Ratings: |
Class I Division 2 Group C, D T3 -40°C≤Tamb≤40°C
|
Standards: |
CSA C22.2 No. 213-17 (R2022)/ UL 121201 Ninth Edition- Non-incendive electrical equipment for use in Class I, II, Div 2
CSA C22.2 No 61010-1-12/UL61010-1-Ed.3- Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use – Part 1: General Requirements |
Conditions of Acceptability: |
- Markings as given in the report on the marking section.
- The unit is a tested and certified as a component piece of equipment and shall be housed in a suitable enclosure.
|