CERTIFICATE OF COMPLIANCE
Certificate Number | INTL-202109-C02 | Project Number: | INTL-202109-C02 |
---|---|---|---|
Date Issued: | January 8, 2023 | Client Number: | INTL-202109 |
Certification System: | Type 3 (ISO/IEC Guide 67) | Issued to: | Acura Embedded Systems Inc. 17825 64 Ave #101, Surrey, BC V3S 1Z3 |
Certification Body: | International Testing Laboratory Inc. | Issued By: | Certification Manager |
The products listed below are eligible to bear the INTL Certification Mark with adjacent indicator 'C' and ‘US’, and the subject area as shown below which represents that the product has been evaluated by an accredited CB to the applicable CSA and UL Standards respectively.
Product: | Industrial Panel PCs and Monitors |
---|---|
Model #: | AcuPanel-10
AcuTouch-10 AcuPanel-12 AcuTouch-12 AcuPanel-15 AcuTouch-15 AcuPanel 15.6 Widescreen AcuTouch-17 AcuPanel-17 AcuTouch-19 AcuPanel-22 AcuTouch-21 AcuPanel-10W AcuBrite 12 AcuPanel-12W AcuBrite 15 AcuPanel-15W AcuBrite-10W AcuPanel-17W AcuBrite-12W AcuPanel-19W AcuBrite-15W AcuPanel-22W AcuBrite-17W RoughNeck-15 AcuBrite-19W RoughNeck-15W AcuBrite- 22W RoughNeck-19W Roughneck-22W |
Electrical Ratings: | Input 100-240Vac 50/60Hz 5A, 2.5A, Input 9-36Vdc
Class I Zone 2 Ex ec IIB T4 Gc -20°C ≤Tamb≤60°C; INTL22CA202109-C02 Class I Zone 2 AEx ec IIB T4 Gc -20°C ≤Tamb≤60°C Class I Division 2 Groups B C D T4 Gc, -20°C ≤ Tamb ≤ 60°C |
Standards: | CAN/CSA-C22.2 NO. 62368-1 (Ed. 2.0)
UL 62368-1 (Ed. 2.0) CSA C22.2 No. 60079-0:19 CSA C22.2 No. 60079-7:16 UL 60079-0 (Ed. 7.0) UL 60079-7 (Ed. 5.0) |
Conditions of Acceptability: | - Panel PCs and Acubrite Monitors are intended to be used indoors environment within ambient temperature of -20C and 60°C.
- When used in location classified as hazardous location. These devices are intended to be installed and operated in an enclosure providing suitable degree of protection in the end application. Where only display side of the unit is intended to be installed in exposed environment. All the connectors shall be inside the enclosure providing suitable degree of protection. - All the connectors shall not be disconnected or connected in an atmosphere where explosive gases are present. - All the buttons, switches or rotary knobs shall not be operated in an atmosphere where explosive gases are present. - Intended to be used with only certified AC-DC power supply adapter as listed in critical component list. - Operating altitude: 2000m - Intended to be used by trained or instructed professionals. |